Electronics
Electrical Products GB 19212.13-2005 Safety of Power Transformers, Power Supply Devices, and Similar
Electrical Products GB 19212.13-2005 Safety of Power Transformers, Power Supply Devices, and Similar
Click here for online message:
Drop us a line
Service@Baijiantest.Com
Electrical Products GB 19212.13-2005 Safety of Power Transformers, Power Supply Devices, and Similar

Scope

This chapter of GB 19212.1-2003 is replaced by the following:

This section specifies the safety requirements for various aspects of transformers (such as electrical, temperature, and mechanical aspects) This section is applicable to stationary or mobile, single-phase or multiphase, air cooled (natural cooling or forced cooling), matched or independent:

- constant voltage autotransformer

- Constant voltage separation transformer

- Constant voltage isolation transformer

- Constant voltage safety isolation transformer Its rated power supply voltage does not exceed 1000 V AC, rated frequency does not exceed 500 Hz, internal operating frequency does not exceed 30 kHz, and there is no rated output limit

Note 1: With the development of transformer technology, it may be necessary to increase the upper limit of internal operation failure rate. At that time, this section can be used as a guide

Constant voltage independent autotransformer:

- The no-load output voltage and rated output voltage exceed AC 50 V or ripple free DC 120 V and do not exceed AC 1000 V

or ripple free DC 1415 V

- Used for transformers that do not require insulation between circuits according to installation regulations or equipment specifications

Autotransformer for constant voltage matching:

- The no-load output voltage and rated output voltage shall not exceed AC 1000 V or ripple free DC 1415 V

Constant voltage independent separation transformer:

- The no-load output voltage and rated output voltage exceed AC 50V or ripple free DC 120V and do not exceed AC 1000 V or ripple free DC 1415 V

- Used for transformers that do not require double insulation or reinforced insulation between circuits according to installation regulations or equipment specifications

Separation transformer for constant voltage matching:

- The no-load output voltage and rated output voltage shall not exceed AC 1000 V or ripple free DC 1415 V

Constant voltage isolation transformer:

- The no-load output voltage and/or rated output voltage exceeds AC 50V or ripple free DC 120V and does not exceed AC 500V

or ripple free DC 708V; In order to comply with national electrical wiring regulations or special purposes, the no-load output voltage and rated output voltage can exceed these limits, but should not exceed 1000 V AC or 1415 ripple free DC

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific, fair, and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

Baijian and testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Testing and testing characteristics:

1. The testing industry is fully covered, meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing, with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle, low cost, and attentive service

7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc

8. The testing report is authoritative and effective, and is generally used in China